Impella RP with SmartAssist heart pump shown in the right ventricle pumping blood on a blue background

Impella RP®

with SmartAssist®
A minimally invasive, right-sided heart pump with intelligent technology to improve patient outcomes with a flow rate greater than 4.0 L/min
 

Overview

The Impella RP with SmartAssist heart pump provides temporary, circulatory support for patients who develop right heart failure. From the platform of the only FDA-approved heart pumps, Impella RP with SmartAssist is indicated for patients experiencing acute right heart failure or decompensation for less than 48 hours following left ventricular assist device implantation, myocardial infarction, heart transplant, or open‐heart surgery, without the presence of profound shock, end organ failure, or acute neurologic injury.

FOR PATIENTS EXPERIENCING

Right Heart Failure

During right heart failure, blood begins to backup because it isn’t adequately pumped out to the lungs. This backup causes pressure in the veins, resulting in swelling of the legs and ankles. Ultimately, the amount of blood reaching the lungs, where blood normally becomes infused with much-needed oxygen, is reduced.

Are you a health care professional?

Visit heartrecovery.com to access instructions for use and other clinical materials.

Indications for Use

PMA Approved Indication

The Impella RP® with SmartAssist® System is indicated for providing temporary right ventricular support for up to 14 days in patients with a body surface area ≥1.5 m2, who develop acute right heart failure or decompensation for less than 48 hours following left ventricular assist device implantation, myocardial infarction, heart transplant, or open‐heart surgery, without the presence of profound shock, end organ failure, or acute neurologic injury.

Contraindications and Warnings

The Impella RP with SmartAssist System is contraindicated for patients with the following conditions: Disorders of the pulmonary artery wall that would preclude placement or correct positioning of the Impella RP devices. Mechanical valves, severe valvular stenosis or valvular regurgitation of the tricuspid or pulmonary valve. Mural thrombus of the right atrium or vena cava. Anatomic conditions precluding insertion of the pump. Presence of a vena cava filter or caval interruption device, unless there is clear access from the femoral vein to the right atrium that is large enough to accommodate a 22Fr catheter.

Potential Adverse Events

The potential adverse effects (eg, complications) associated with the use of Impella RP with SmartAssist: Arrhythmia, Atrial fibrillation, Bleeding, Cardiac tamponade, Cardiogenic shock, Death, Device malfunction, Hemolysis, Hepatic failure, Insertion site infection, Perforation, Phlegmasia cerulea dolens (a severe form of deep venous thrombosis), Pulmonary valve insufficiency, Respiratory dysfunction, Sepsis, Thrombocytopenia, Thrombotic vascular (non-central nervous system) complication, Tricuspid valve injury, Vascular injury, Venous thrombosis, Ventricular fibrillation and/or tachycardia.